Availability: | |
---|---|
Quantity: | |
Phase: Three Phase
High Voltage: 110kV-138kV
Low Voltage: 6.3kV-21kV
Rated Capacity: 6300kVA-63000kVA
Vector Group: YNd11, YNyn0, d11
This medium voltage transformer has many models to choose from, please refer to the enclosed brochure for technical parameters.
Low Loss: No-load loss is reduced by 20% compared to national standards, and load loss is reduced by 5%.
Low Noise: Natural cooling noise levels are below 60dB, 3 to 5dB lower than national standards.
Low Partial Discharge: Dust-free operations keep partial discharge levels below 100pC.
Short Circuit Resistance: Passed sudden short circuit tests at the National Transformer Testing Center.
Leakage-Free: All sealing components are made from acrylic in one piece and undergo fluorescence, positive pressure, and negative pressure leak tests.
A hybrid insulation of Nomex® paper + transformer oil, providing the following operational capabilities at various ambient temperatures (°C):
Ambient Temperature (℃) | -10 | 0 | 10 | 20 | 30 | 40 |
S9 (K24) | 1.25 | 1.17 | 1.09 | 1 | 0.91 | 0.81 |
SRN (K24) | 1.37 | 1.3 | 1.25 | 1.18 | 1.10 | 1.00 |
We ensure optimal performance and reliability under various conditions through advanced temperature control of insulation materials, liquid flow circuits, overload protection, iron cores, seals, components, and short circuits.
Utilizes a fully enclosed manufacturing process with constant temperature and humidity control in a dust-free environment, ensuring meticulous quality control.
The core material is high magnetic permeability silicon steel, produced using a fully automated Swiss-imported cross-cutting and stacking robot production line.
The coil's guided oil circulation structure ensures a product design lifespan of 30 years.
The tank adopts a minute bell-type and barrel-type structure with precise sealing limits and undergoes three leak tests.
Phase: Three Phase
High Voltage: 110kV-138kV
Low Voltage: 6.3kV-21kV
Rated Capacity: 6300kVA-63000kVA
Vector Group: YNd11, YNyn0, d11
This medium voltage transformer has many models to choose from, please refer to the enclosed brochure for technical parameters.
Low Loss: No-load loss is reduced by 20% compared to national standards, and load loss is reduced by 5%.
Low Noise: Natural cooling noise levels are below 60dB, 3 to 5dB lower than national standards.
Low Partial Discharge: Dust-free operations keep partial discharge levels below 100pC.
Short Circuit Resistance: Passed sudden short circuit tests at the National Transformer Testing Center.
Leakage-Free: All sealing components are made from acrylic in one piece and undergo fluorescence, positive pressure, and negative pressure leak tests.
A hybrid insulation of Nomex® paper + transformer oil, providing the following operational capabilities at various ambient temperatures (°C):
Ambient Temperature (℃) | -10 | 0 | 10 | 20 | 30 | 40 |
S9 (K24) | 1.25 | 1.17 | 1.09 | 1 | 0.91 | 0.81 |
SRN (K24) | 1.37 | 1.3 | 1.25 | 1.18 | 1.10 | 1.00 |
We ensure optimal performance and reliability under various conditions through advanced temperature control of insulation materials, liquid flow circuits, overload protection, iron cores, seals, components, and short circuits.
Utilizes a fully enclosed manufacturing process with constant temperature and humidity control in a dust-free environment, ensuring meticulous quality control.
The core material is high magnetic permeability silicon steel, produced using a fully automated Swiss-imported cross-cutting and stacking robot production line.
The coil's guided oil circulation structure ensures a product design lifespan of 30 years.
The tank adopts a minute bell-type and barrel-type structure with precise sealing limits and undergoes three leak tests.